This page is part of archived documentation for openHAB 3.2. Go to the current stable version

# Teleinfo Binding

The Teleinfo binding supports an interface to ENEDIS/ERDF Teleinfo protocol (opens new window) for (French) Electricity Meter. This binding works with a Teleinfo modem plugged to the I1 and I2 terminals of your electricity meter. Teleinfo modems can be ordered (see the list of tested hardware below) or build by yourself (see this example (opens new window)).

Teleinfo is a protocol to read many electrical statistics of your electricity meter: instantaneous power consumption, current price period, meter reading... These values can be used to

  • send your meter reading to your electricity provider with a simple copy/paste,
  • improve your rules and minimize electricity costs,
  • check if your subscription is relevant for your needs,
  • monitor your electricity consumption,

# Supported Things

# Historical TIC mode

Historical TIC mode is the only mode of all telemeters before Linky models and the default mode for Linky telemeters.

The Teleinfo binding provides support for both single-phase and three-phase connection, ICC evolution and the following pricing modes:

  • HCHP mode
  • Base mode
  • Tempo mode
  • EJP mode
Thing type Connection Pricing mode ICC evolution
cbemm_base_electricitymeter single-phase Base
cbemm_ejp_electricitymeter single-phase EJP
cbemm_hc_electricitymeter single-phase HCHP
cbemm_tempo_electricitymeter single-phase Tempo
cbemm_evolution_icc_base_electricitymeter single-phase Base [x]
cbemm_evolution_icc_ejp_electricitymeter single-phase EJP [x]
cbemm_evolution_icc_hc_electricitymeter single-phase HCHP [x]
cbemm_evolution_icc_tempo_electricitymeter single-phase Tempo [x]
cbetm_base_electricitymeter three-phase Base
cbetm_ejp_electricitymeter three-phase EJP
cbetm_hc_electricitymeter three-phase HCHP
cbetm_tempo_electricitymeter three-phase Tempo

# Standard TIC mode

Linky telemeters add a new Standard mode with more detailed information but still provide information on the legacy format under the Historical denomination.

Standard mode doesn't depend on the pricing options, but it adds some useful information for electricity producers.

Thing type Connection Producer mode
lsmm_electricitymeter single-phase
lsmm_prod_electricitymeter single-phase [x]
lstm_electricitymeter three-phase
lstm_prod_electricitymeter three-phase [x]

# Discovery

Before the binding can be used, a serial controller must be added. This needs to be done manually. Select Teleinfo Serial Controller and enter the serial port.

If you want to place the Teleinfo modem apart from your openHAB server, you can forward its serial messages over TCP/IP (ser2net). In this case you have to define the serial port of your Teleinfo modem like this rfc2217://ip:port. When using ser2net make sure to use telnet instead of raw in the ser2net config file.

Once the serial controller added, electricity meters will automatically appear after starting discovery, with default label Teleinfo ADCO #adco where #adco is your electricity meter identifier.

# Thing Configuration

Thing type Parameter Meaning Possible values
serialcontroller serialport Path to the serial controller /dev/ttyXXXX, rfc2217://ip:port
*_electricitymeter adco Electricity meter identifier 12 digits number
ticMode TIC mode STANDARD, HISTORICAL (default)

# Channels

# Historical TIC mode

Channel availability depends on the electricity connection (single or three-phase) and on the pricing mode (Base, HCHP, EJP or Tempo).

Channel Type Description Connection Mode
isousc Number:ElectricCurrent Subscribed electric current All All
ptec String Current pricing period All All
imax Number:ElectricCurrent Maximum consumed electric current Single-phase All
imax1 Number:ElectricCurrent Maximum consumed electric current on phase 1 Three-phase All
imax2 Number:ElectricCurrent Maximum consumed electric current on phase 2 Three-phase All
imax3 Number:ElectricCurrent Maximum consumed electric current on phase 3 Three-phase All
adps Number:ElectricCurrent Excess electric current warning Single-phase All
adir1 Number:ElectricCurrent Excess electric current on phase 1 warning Three-phase All
adir2 Number:ElectricCurrent Excess electric current on phase 2 warning Three-phase All
adir3 Number:ElectricCurrent Excess electric current on phase 3 warning Three-phase All
iinst Number:ElectricCurrent Instantaneous electric current Single-phase All
iinst1 Number:ElectricCurrent Instantaneous electric current on phase 1 Three-phase All
iinst2 Number:ElectricCurrent Instantaneous electric current on phase 2 Three-phase All
iinst3 Number:ElectricCurrent Instantaneous electric current on phase 3 Three-phase All
ppot String Electrical potential presence Three-phase All
pmax Number:Energy Maximum consumed electric power on all phases Three-phase All
papp Number:Power Instantaneous apparent power Three-phase, single-phase (ICC evolution only) All
hhphc String Pricing schedule group All HCHP
hchc Number:Energy Total consumed energy at low rate pricing All HCHP
hchp Number:Energy Total consumed energy at high rate pricing All HCHP
base Number:Energy Total consumed energy All Base
ejphn Number:Energy Total consumed energy at low rate pricing All EJP
ejphpm Number:Energy Total consumed energy at high rate pricing All EJP
bbrhcjb Number:Energy Total consumed energy at low rate pricing on blue days All Tempo
bbrhpjb Number:Energy Total consumed energy at high rate pricing on blue days All Tempo
bbrhcjw Number:Energy Total consumed energy at low rate pricing on white days All Tempo
bbrhpjw Number:Energy Total consumed energy at high rate pricing on white days All Tempo
bbrhcjr Number:Energy Total consumed energy at low rate pricing on red days All Tempo
bbrhpjr Number:Energy Total consumed energy at high rate pricing on red days All Tempo
pejp Number:Duration Prior notice to EJP start All EJP
demain String Following day color All Tempo

# Standard TIC mode

Channel Type Description Connection Mode
ngtf String Provider schedule name All All
ltarf String Current pricing label All All
east Number:Energy Total active energy withdrawn All All
easfXX Number:Energy Active energy withdrawn from provider on index All All
easdXX Number:Energy Active energy withdrawn from distributor on index All All
irmsX Number:ElectricCurrent RMS Current on phase X All for , Three-phase for All
urmsX Number:Potential RMS Voltage on phase X All for , Three-phase for All
pref Number:Power Reference apparent power All All
pcoup Number:Power Apparent power rupture capacity All All
sinsts Number:Power Instantaneous withdrawn apparent power Single-phase All
smaxsn Number:Power Maximum withdrawn apparent power of the day Single-phase All
smaxsnMinus1 Number:Power Maximum withdrawn apparent power of the previous day Single-phase All
ccasn Number:Power Active charge point N All All
ccasnMinus1 Number:Power Active charge point N-1 All All
umoyX Number:Potential Mean Voltage on phase X All for , Three-phase for All
dpmX String Start of mobile peak period All All
fpmX String End of mobile peak period All All
msg1 String Short message All All
msg2 String Very short message All All
ntarf String Index of current pricing All All
njourf String Number of current provider schedule All All
njourfPlus1 String Number of next day provider schedule All All
pjourfPlus1 String Profile of next day provider schedule All All
ppointe String Profile of next rush day All All
date DateTime Date and Time All All
smaxsnDate DateTime Timestamp of SMAXSN value All All
smaxsnMinus1Date DateTime Timestamp of SMAXSN-1 value All All
ccasnDate DateTime Timestamp of CCASN value All All
ccasnMinus1Date DateTime Timestamp of CCASN-1 value All All
umoyXDate DateTime Timestamp of UMOYX value All for , Three-phase for All
dpmXDate DateTime Date of DPMX All All
fpmXDate DateTime Date of FPMX All All
relaisX Switch relais status ( ) All All
sinstsX Number:Power Instantaneous withdrawn apparent power on phase X Three-phase All
smaxsnX Number:Power Maximum withdrawn apparent power of the day on phase X Three-phase All
smaxsnXMinus1 Number:Power Maximum withdrawn apparent power on the previous day on phase X Three-phase All
smaxsXnDate DateTime Timestamp of SMAXSNX value Three-phase All
smaxsnXMinus1Date DateTime Timestamp of SMAXSNX-1 value Three-phase All
eait Number:Energy Total active energy withdrawn All All
erqX Number:Energy Active energy withdrawn from provider on index All All
sinsti Number:Energy Active energy withdrawn from distributor on index All All
smaxin Number:Power Maximum injected apparent power of the day All for , Three-phase for All
smaxinMinus1 Number:Power Maximum injected apparent power of the previous day All for , Three-phase for All
ccain Number:Power Injected active charge point N All Producer
ccainMinus1 Number:Power Injected active charge point N-1 All Producer
smaxinDate DateTime Timestamp of SMAXIN value All Producer
smaxinMinus1Date DateTime Timestamp of SMAXIN-1 value All Producer
ccainDate DateTime Timestamp of CCAIN value All Producer
ccainMinus1Date DateTime Timestamp of CCAIN-1 value All Producer

# Full Example

# Historical TIC mode

The following things file declare a serial USB controller on /dev/ttyUSB0 for a Single-phase Electricity meter with HC/HP option - CBEMM Evolution ICC and adco 031528042289 :

Bridge teleinfo:serialcontroller:teleinfoUSB [ serialport="/dev/ttyUSB0" ]{
    Thing cbemm_evolution_icc_hc_electricitymeter myElectricityMeter [ adco="031528042289"]
}

adco is a 12-digit number written on the electricity meter (There might be two additional digits on the electricity meter, in this case the two last digits must be omitted to obtain 12 digits). The first 6 digits of adco can also be retrieved by pushing 6 times the selection button of your electricity meter, and the last 6 digits by pushing the defilement button.

This items file links some supported channels to items:

Number:Power TLInfoEDF_PAPP "PAPP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:papp"}
Number:ElectricCurrent TLInfoEDF_ISOUSC "ISOUSC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:isousc"}
String TLInfoEDF_PTEC "PTEC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:ptec"}
Number:ElectricCurrent TLInfoEDF_IMAX "IMAX" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:imax"}
Number:ElectricCurrent TLInfoEDF_ADPS "ADPS" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:adps"}
Number:ElectricCurrent TLInfoEDF_IINST "IINST" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:iinst"}
Number:Energy TLInfoEDF_HCHC "HCHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchc"}
Number:Energy TLInfoEDF_HCHP "HCHP" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hchp"}
String TLInfoEDF_HHPHC "HHPHC" <energy> {channel="teleinfo:cbemm_evolution_icc_hc_electricitymeter:teleinfoUSB:myElectricityMeter:hhphc"}

# Tested hardware

The Teleinfo binding has been successfully validated with below hardware configuration:

Serial interface Power Energy Meter model Mode(s)
GCE Electronics USB Teleinfo module (more details) (opens new window) Actaris A14C5 Single-phase HCHP & Base
Cartelectronic USB Teleinfo modem (more details) (opens new window) Sagem S10C4 Single-phase HCHP

On Linky telemeters, only historical TIC mode is currently supported. The method for changing the TIC mode of a Linky telemeter is explained here (opens new window).